Copper foil tape for EMI shielding and grounding: why the adhesive has to conduct
By the LJIPL Mr.Bond® team · Updated
A copper foil tape used for EMI shielding only works if its adhesive conducts. The foil itself is never the weak point; the overlaps are. With an ordinary insulating acrylic adhesive, every lap joint in a wrapped harness or a taped seam becomes an electrical break, so the shield looks continuous and behaves as a row of disconnected patches. Mr.Bond® Copper Foil Tape is coated with an electrically conductive, pressure-sensitive acrylic adhesive, so current passes through the glue line between overlapping layers and the shield stays continuous across joints. It is specially designed for EV application at a thickness of 65 to 70 micron, passes the 2-point test method and bears a temperature range of T2. No shielding effectiveness figure in decibels and no surface resistance value is published for this grade. It is manufactured in India by Lalit Jain Industries Pvt. Ltd. (LJIPL).
What is a shield actually doing?
EMI is electromagnetic interference: the electrical noise a circuit radiates. EMC, electromagnetic compatibility, is the requirement that a piece of equipment neither emits too much of that noise nor is upset by what reaches it from elsewhere. One of them is a physical phenomenon, the other is a condition you have to satisfy.
A shield is a conductive surface placed between a noise source and whatever must not hear it. It works by giving the energy somewhere else to go: currents are induced in the conductive layer and the field on the far side is reduced. Two consequences fall out of that mechanism and both are practical.
First, the shield has to be continuous. A conductive surface with an electrically open slot in it stops behaving like a sheet at the frequencies where that slot matters, which is why in enclosure design a seam is treated as a component rather than as a line on a drawing. Second, the shield usually has to be connected. Induced currents need a path back to a reference potential, and a shield left electrically floating is doing a fraction of the job it could do.
Everything that follows about copper foil tape comes from those two requirements: it has to stay continuous across its own overlaps, and it has to be bondable to the thing it is referenced against.
| What you need | Why | Published for Mr.Bond® Copper Foil Tape |
|---|---|---|
| A conductive adhesive | Otherwise every overlap is an electrical break in the shield | Electrically conductive, pressure-sensitive acrylic adhesive |
| A foil thin enough to conform | A foil that lifts at edges and corners leaves the seam open | 65 to 70 micron |
| Suitability for the application | An EV assembly is a harder environment than a bench fix | Specially designed for EV application |
| A temperature qualification | Continuous service, not a momentary peak | Bears temperature range of T2 |
| A test qualification | Evidence the grade is made to a repeatable standard | Passes the 2-point test method |
| Shielding effectiveness in dB | Only meaningful against a stated method, frequency and fixture | Not published, raise the requirement in your enquiry |
| Surface or contact resistance | Depends on substrate, pressure and surface finish in your build | Not published, raise the requirement in your enquiry |
Why does the adhesive have to conduct?
This is the detail that decides whether a foil tape is a shielding product or simply a copper-coloured one.
A standard acrylic pressure-sensitive adhesive is an insulator. Apply a foil tape with that adhesive, overlap it the way any tape has to be overlapped to wrap a bundle or cross a seam, and you have put a thin insulating layer between two pieces of copper at every lap. The foil is electrically continuous along each strip and open between strips. To the eye the shield is complete; electrically it is a series of islands, and a shield is only as good as its worst joint.
Mr.Bond® Copper Foil Tape is coated with an electrically conductive, pressure-sensitive acrylic adhesive. Current passes through the glue line from one layer of foil to the next, so a spiral-wrapped harness or a taped enclosure seam behaves as a single shield instead of a row of patches. It is also what allows the tape to be used as a connection rather than only as a covering.
Pressure-sensitive is the other half of the description and it matters on a line: the tape needs only firm hand or roller pressure to bond, with no heat, no solvent and no cure time. The corollary is that the bond is only as good as the pressure and the surface. A conductive adhesive pressed lightly onto an oxidised or oily surface will give a poor electrical joint while looking perfectly well stuck, which is the most common way a correctly specified shielding tape still underperforms.
Where is copper foil tape used?
Wherever a conductive layer has to be added to something that was not made with one, or has to bridge a gap in one that was.
In electric vehicle work that means shielding around control electronics and power conversion, where devices switch hard and fast and the radiated noise has to be contained rather than allowed into neighbouring circuits. The Mr.Bond® grade is specially designed for EV application. Typical locations are harness and cable wrapping, enclosure and cover seams, screening over or around a board area, and shield terminations where a braid or a foil screen has to be carried onto a chassis.
In electronics assembly more generally the same tape screens sensitive sections of a board, lines a plastic housing to give it a conductive interior, patches a gap left by a cut-out or a connector aperture, and makes low-current connections on flexible and awkward geometry. The surrounding materials for that work, Class H and Class 180°C insulation, cotton coil wrapping, foam mounting and flame-rated bonding, are listed on the electronics industry page.
Inside a battery pack, shielding is one of five or six separate jobs the tapes are doing. The reasoning for each is set out in tapes inside an EV battery pack, job by job, and the product-by-product version is on the EV battery tapes hub.
Why does 65 to 70 micron matter?
It is a conformability figure much more than a conductivity one, and that is worth being clear about, because thickness is routinely mistaken for shielding performance.
A micron is one thousandth of a millimetre, so 65 to 70 micron is a thin foil. Thin matters because a shielding tape has to go round things: a cable bundle, the radius of a folded cover, the inside corner of an enclosure. A heavier foil resists being formed, and a foil that resists being formed lifts at the edges and springs away from corners, and a lifted edge is a broken shield in exactly the place a seam most needed to be closed.
Thin also means the tape takes up little space in an assembly that has none to give, and adds almost nothing to the mass of a wrapped harness. Against that, a foil can be made too thin to handle: it tears on application, creases instead of conforming, and will not take the pressure a conductive adhesive needs. The published thickness is where the tape sits between those two problems.
The other two published qualification figures for this grade are that it passes the 2-point test method and bears a temperature range of T2. Those are the figures we hold for the grade; see the next section for what we deliberately do not quote.
What about grounding, as distinct from shielding?
Shielding and grounding are related but they are not the same requirement, and conflating them is a common source of disappointment with a foil tape.
Shielding is about putting a conductive surface in the way. Grounding, in the sense used on an EMC drawing, is about tying that surface to a defined reference potential so the currents induced in it have a path. A shield with no reference connection still reflects some energy, but it cannot do the job a bonded shield does, and in some configurations an unreferenced conductor placed near a noisy circuit makes matters worse rather than better.
Because its adhesive conducts, a copper foil tape can serve as the bond as well as the barrier: a strip run from a shield onto a chassis, a tab taken from a screened area to a grounding point, or a lap that carries a braid termination onto a panel, all without a soldering iron and all on geometry that would be awkward to solder. That is a genuine advantage of the construction and it is why foil tape appears on EMC fixes as often as on EMC designs.
What it is not is a substitute for a designed bond where the specification calls for one. If a drawing specifies a bond impedance, a joint resistance or a measured shielding effectiveness, a taped connection has to be verified against that figure in your assembly rather than assumed from a datasheet. Describe the requirement in the enquiry and it will be addressed directly.
What should you specify, and what do we not publish?
Start with the honest part. We publish no shielding effectiveness figure in decibels and no surface or contact resistance value for this tape. Those numbers are meaningful only against a stated test method, frequency range and fixture, and quoting one without that context would be worse than quoting nothing. If your specification requires a measured figure, say so in the enquiry and it will be addressed directly rather than estimated. Competitor figures are theirs and are measured on their product, not ours.
What to send instead:
Width and roll length. Custom slitting runs from 12 mm to 1200 mm, and the width that suits a cable bundle is rarely the width that suits an enclosure seam. The substrate. Painted steel, anodised aluminium, bare metal, plastic and a braided screen all behave differently under a conductive adhesive, and anodising in particular is an insulating surface finish. The temperature at the location, continuous rather than peak. The geometry: flat seam, outside radius, inside corner, or a spiral wrap on a bundle, because that is what sets the width and the thickness discussion. Whether the tape is carrying a connection or only acting as a barrier, because a bonded shield has a verification requirement a barrier does not. And any compliance requirement written into your specification.
Copper Foil Tape is manufactured by Lalit Jain Industries Pvt. Ltd. (LJIPL), founded in 1987 and ISO 9001:2015 certified, at two of its own units at Rai, Sonipat (Haryana) and Bawana, Delhi. Samples are available on request and every reel carries its full advertised length. Send the details above to our engineering team for a quote.
Frequently asked questions
Why does copper foil tape need a conductive adhesive?
Because the overlaps are where a taped shield fails. An ordinary acrylic adhesive is an insulator, so it puts a thin insulating layer between two pieces of copper at every lap joint. Mr.Bond® Copper Foil Tape uses an electrically conductive, pressure-sensitive acrylic adhesive, so current passes through the glue line and the shield stays continuous.
What is the difference between EMI shielding and grounding?
Shielding puts a conductive surface between a noise source and what must not hear it. Grounding ties that surface to a defined reference potential so induced currents have a path. A shield with no reference connection cannot do the job a bonded shield does. Because its adhesive conducts, foil tape can serve as both the barrier and the bond.
How thick is Mr.Bond® copper foil tape?
65 to 70 micron. That is a conformability figure more than a conductivity one: a thin foil wraps a cable bundle and presses into an inside corner without lifting at the edges, and a lifted edge is a broken shield. It also adds almost nothing to the space or mass of a wrapped harness.
What shielding effectiveness in dB does the tape provide?
No shielding effectiveness figure in decibels is published for this grade, and no surface resistance value either. Such figures are only meaningful against a stated test method, frequency range and fixture. If your specification requires a measured figure, raise it in your enquiry and it will be addressed directly rather than estimated.
Where is copper foil tape used?
Wrapping cables and harnesses, closing enclosure and cover seams, screening areas of a board, lining a plastic housing to give it a conductive interior, patching gaps left by cut-outs and apertures, and carrying shield terminations onto a chassis. This grade is specially designed for EV application and is also used in general electronics assembly.
Does the surface matter when applying a conductive adhesive?
Very much. A conductive adhesive pressed lightly onto an oxidised, oily or anodised surface gives a poor electrical joint while looking well stuck. Anodising in particular is an insulating finish. Name the substrate in your enquiry and apply the tape to a clean, dry surface with firm roller pressure.
What should I send with a copper foil tape enquiry?
The width and roll length, the substrate the tape has to bond to, the continuous temperature at the location, the geometry it has to follow, whether the tape is carrying a connection or only acting as a barrier, and any compliance figure in your specification. Custom slitting runs from 12 mm to 1200 mm.
Who manufactures this copper foil tape?
Lalit Jain Industries Pvt. Ltd. (LJIPL), founded in 1987 and ISO 9001:2015 certified, at two of its own units at Rai, Sonipat in Haryana and Bawana in Delhi. Copper foil tapes are listed in the LJIPL catalogue alongside the other products made for the EV battery industry.