Thermal pads vs thermal tapes: what does a thermal interface material actually do?
By the LJIPL Mr.Bond® team · Updated
A thermal interface material sits between a component that makes heat and the structure meant to carry that heat away. It exists because two surfaces pressed together only touch at their high points, and the air trapped in between is a poor conductor. A thermal pad is the version specified by a number: LJIPL Mr.Bond® thermal pads offer good thermal conductivity with low thermal resistance, are UL 94V0 approved, and can be supplied from 1 W/m·K to 8 W/m·K as per your specification. A foam-based thermal tape such as Prateek® Nitrile Foam Tape is specified by its job instead: it helps transfer heat away from battery cells and ensures consistent thermal connections within the battery pack. Choose the pad when a conductivity figure is written into the design, and the foam tape when the requirement is a compliant, consistent interface. Both are made in India by Lalit Jain Industries Pvt. Ltd.
Why a thermal interface is needed at all
Put two flat metal surfaces together and they do not really touch. Machining marks, surface waviness and tolerance variation mean contact happens at high points, and the rest of the joint is air. Air is a poor conductor of heat, so most of the joint is doing nothing.
A thermal interface material fills that space. It deforms into the low spots, displaces the air and gives heat a continuous path from the source into the structure. That is the whole mechanism, and everything else, conductivity figures, thickness, softness, is detail in service of it.
In a battery pack the source is the cell and the destination is the casing or cooling structure. LJIPL Mr.Bond® thermal pads are used between battery cells and casing for exactly this reason.
| Question | Mr.Bond® Thermal Pads | Prateek® Nitrile Foam Tape |
|---|---|---|
| How is it specified? | By thermal conductivity, 1 W/m·K to 8 W/m·K per specification | By function, as a thermal interface material |
| Fire rating | UL 94V0 approved, the highest rating for fire resistance | Not published; confirm against your specification |
| Where it sits | Between battery cells and casing | Between cells and surrounding structure in the pack |
| Mechanical role | Allows cell expansion and contraction; aids in securing cells under vibration | Compressible foam keeps thermal connections consistent |
| Supply form | Readily available stocks in roll form; sizes and thicknesses customisable | Supplied in tape form for assembly |
What W/m·K means, and why a range exists
W/m·K, watts per metre kelvin, measures how readily a material conducts heat. A higher figure means more heat crosses the same thickness for the same temperature difference.
Mr.Bond® thermal pads can be offered from 1 W/m·K to 8 W/m·K as per your specification. A range is offered rather than a single grade because packs differ: heat loads, gaps and contact pressures are not the same from one design to the next, and the most conductive pad is not automatically the right answer for a given assembly.
The practical approach is to start from the thermal model. If your design calls for a specific conductivity, that number drives the specification. If it does not, the conversation starts from the gap, the footprint and the heat load instead.
Pads: specified by number, approved for fire
A thermal pad is the product you reach for when the requirement is written down. Mr.Bond® pads offer good thermal conductivity and low thermal resistance while remaining an excellent insulation material, conducting heat while not conducting electricity, which is the combination a pack needs.
They are UL 94V0 approved, the highest rating for fire resistance. For a material sitting inside a sealed enclosure in direct contact with cells, that is normally a requirement rather than a bonus.
They also do mechanical work. Being compressible, a pad allows for expansion and contraction of cells during charging and discharging, and aids in securing the cells in position when vibrations occur. Readily available stocks are held in roll form, and sizes and other thicknesses can be customised as per requirements.
Foam thermal tapes: specified by the job
Prateek® Nitrile Foam Tape is used as a thermal interface material. Its published function is to help transfer heat away from battery cells and to ensure consistent thermal connections within the battery pack.
Notice that it is described by what it does rather than by a conductivity figure. That is the practical difference between the two product families. A foam tape is chosen where the requirement is a compliant, consistent interface that takes up variation between parts; a pad is chosen where the requirement is a number.
Foam suits this because battery assemblies move. Cells change dimension as they charge and discharge, tolerances stack up across a module, and packs vibrate in service. A compressible interface keeps contact through all of that; a rigid one cannot.
Related materials that are not thermal interfaces
It is worth separating the thermal materials from the ones that look similar. LKJ® EVA Double-Sided Foam Tape is a mounting product: it ensures stable adhesion when fixing circuit boards, battery cells and displays within the battery assembly. Single-sided foam tape in EVA and PE base foams is for insulation purposes, reducing vibration and blocking noise.
Neither is specified as a thermal interface material, and neither should be substituted for one. Equally, an insulation tape such as Mr.Bond® Polyimide Tape is specified for its Class 180°C rating, flame-retardant grade and dielectric strength, it manages heat by tolerating it, not by conducting it away.
How to specify what you need
Send four things with your enquiry: the gap the material has to fill, the footprint or pad size, the heat load or the conductivity your design calls for, and the flammability requirement in your specification. If the material sits in a location that moves, against cells that expand and contract, or in an assembly that vibrates, say so, because that is what pushes the choice towards a compressible material.
Both products are manufactured by Lalit Jain Industries Pvt. Ltd. (LJIPL), an ISO 9001:2015 certified manufacturer founded in 1987, at its units in Rai, Sonipat (Haryana) and Bawana, Delhi. Sizes and thicknesses are customised as per requirements and quoted against your specification.
Frequently asked questions
What is a thermal interface material?
It is a layer placed between a heat-producing component and the structure that carries heat away. Two surfaces pressed together touch only at high points and the trapped air conducts poorly. A conformable interface fills those gaps so heat has a continuous path across the whole joint.
What does W/m·K mean on a thermal pad?
Watts per metre kelvin, the standard measure of thermal conductivity. A higher figure means more heat passes through the same thickness of material for the same temperature difference. Mr.Bond® thermal pads can be offered from 1 W/m·K to 8 W/m·K as per your specification.
Should I use a thermal pad or a foam thermal tape?
If your design calls out a thermal conductivity figure, use a thermal pad, since pads are specified by that number. If the requirement is a compliant, consistent interface that takes up variation between parts, a nitrile foam thermal interface tape is the product designed for that job.
Are thermal pads electrically insulating?
LJIPL Mr.Bond® thermal pads are described as an excellent insulation material with good thermal conductivity and low thermal resistance. Conducting heat while not conducting electricity is the combination a battery pack needs from a material sitting between cells and casing.
Why does a thermal material need to be compressible?
Because the assembly moves. Cells expand and contract during charging and discharging, tolerances vary between parts, and packs vibrate in service. A compressible material keeps contact through all of that, while a rigid one loses contact at one extreme and the thermal path with it.
Can thermal pads be supplied in custom sizes?
Yes. Readily available stocks are held in roll form, and sizes and other thicknesses can be customised as per requirements. Send the footprint, the gap to be filled and the conductivity your design calls for and the pad will be specified and quoted against that requirement.