Guide

What does UL 94 V-0 mean on a tape?

By the LJIPL Mr.Bond® team · Updated

Quick answer

UL 94 is the standard classification for the flammability of plastic materials, and V-0 is the most demanding of its vertical burn ratings. The test is narrow and specific: a bar-shaped specimen is clamped vertically, a small flame is applied to its lower end twice for ten seconds each time, and the laboratory records how long the specimen keeps burning after each application, whether it glows afterwards, whether burning drips fall and ignite a cotton indicator beneath, and whether the flame reaches the clamp. V-0, V-1 and V-2 differ in how much of that behaviour is allowed. A V-0 classification says a material self-extinguishes quickly and does not drip flaming particles that start a second fire; it does not say the material is fireproof, non-combustible or safe at any temperature. Mr.Bond® 4500 FLR and LJIPL Mr.Bond® thermal pads are UL 94 V0 approved.

What is UL 94, and what does it actually test?

UL 94 is a flammability classification for plastic materials used in devices and appliances. It is not a rating of a finished product and it is not a fire-safety approval for an assembly; it is a way of putting a comparable label on how a material behaves when a small flame is held against a small specimen of it under controlled conditions.

The familiar V classifications come from the vertical burning test. A set of bar-shaped specimens is clamped at the upper end so each one hangs vertically. A defined small burner flame is applied to the lower end of the specimen for ten seconds and removed, and the laboratory times how long the specimen continues to burn. The flame is then applied a second time for ten seconds and the same measurements are taken, together with the afterglow.

Four behaviours are recorded, and all four have to be satisfied for a classification: how long the specimen keeps burning after each flame application; the total burning time across the whole set of specimens; whether the burning reaches the holding clamp; and whether flaming particles drip from the specimen and ignite a layer of surgical cotton placed a fixed distance below it.

That last one is the detail most people miss, and it is often the one that separates two materials that look similar on a datasheet. The dripping test is asking a different question from the burning test: not “does this material burn” but “does this material start a fire somewhere else while it burns”.

How the UL 94 vertical burn classifications differ (criteria are defined by the standard, confirm against its current edition)
ClassificationAfterflame per specimenTotal afterflame for the specimen setFlaming drips that ignite the cotton
V-0 About 10 seconds, the shortest of the three About 50 seconds Not permitted
V-1 About 30 seconds About 250 seconds Not permitted
V-2 The same allowance as V-1 The same allowance as V-1 Permitted, this is what separates V-2 from V-1
HB (horizontal) A different test: specimens burn horizontally, assessed on burn rate Not applicable Not assessed in the same way

What does the V in V-0 stand for?

Vertical. The V classifications come from the vertical burning test described above, which is why they are quoted as V-0, V-1 and V-2 and why a horizontal-burn classification (HB) is a different and less demanding thing entirely.

The number is the severity grade and it runs the opposite way to intuition: a lower number is the more demanding classification. V-0 is the hardest of the three to achieve, V-2 the easiest. A datasheet quoting V-2 is not quoting a better result than one quoting V-0.

The hyphen is a formality. The standard writes the classifications as V-0, V-1 and V-2; datasheets, purchase specifications and our own product pages commonly drop it and write V0. They mean the same classification. Our Mr.Bond® 4500 FLR is described as UL 94 V0 approved, and LJIPL Mr.Bond® thermal pads as UL 94V0 approved; both refer to the V-0 classification.

How do V-0, V-1 and V-2 differ?

In two respects: how long burning is allowed to continue, and whether flaming drips are permitted at all.

On timing, V-0 is the strictest. A V-0 specimen must stop burning within about ten seconds of each flame application, and the total afterflame across the whole specimen set is limited to roughly fifty seconds. V-1 allows about thirty seconds per specimen and a correspondingly larger total of around two hundred and fifty seconds. V-2 allows the same timings as V-1, it is not a looser timing grade.

On dripping, V-0 and V-1 both require that no flaming particles fall and ignite the cotton indicator beneath the specimen. V-2 permits exactly that. This is the real distinction between V-1 and V-2, and it is the one that tends to matter in a sealed enclosure: a material that self-extinguishes in a reasonable time but drips burning polymer onto whatever sits below it has moved the problem rather than contained it.

None of the three classifications requires that the specimen not burn. All three allow a specimen to be ignited and to burn for a period. A V-0 material is one that stops promptly and does not propagate downwards; it is not a non-combustible one.

The table above sets out the pattern. The exact limits, specimen dimensions, conditioning and specimen count are defined in the standard itself, and the standard is revised over time, so for a design decision, work from the current edition of UL 94 and from your own specification rather than from any summary, including this one.

Why do battery and electronics assemblers ask for it?

Because a flammability class is usually something they have inherited rather than chosen, and it has to be evidenced for every material in the build.

An electrical or electronic assembly that carries a flammability requirement does not get to apply that requirement only to its large plastic parts. Enclosures, mouldings, insulation, potting, labels, foams, gaskets and the adhesive tapes inside them are all materials in the enclosure, and a specification that calls for a class generally calls for it throughout. A single unrated tape inside an otherwise compliant build becomes an exception that somebody has to justify in writing.

There is also a physical reason, and it is specific to the two places we see the requirement most. A battery pack is a sealed enclosure containing a stored-energy device, and almost everything inside it is inaccessible once the pack is closed. A material placed in direct contact with cells cannot be inspected, cannot be replaced easily, and in a thermal event would be among the first things exposed. That is why, for LJIPL Mr.Bond® thermal pads, which are fitted between the battery cells and the casing, the UL 94V0 approval is normally a design requirement rather than a preference, and the first thing a pack designer looks for on the datasheet.

In electronics assembly the same logic applies around boards and power supplies, where a bonded part has to meet the flame requirement of the assembly it is bonded into. The other materials used in that work are listed on the electronics industry page.

Which Mr.Bond® products carry the rating?

Two, and we are deliberate about not extending the claim beyond them.

Mr.Bond® 4500 FLR is a fire-proof double-sided tissue tape with excellent adhesion, UL 94 V0 approved for flame retardancy. FLR in the name stands for flame retardant. It exists because most bonding tapes force a choice: a tape with excellent adhesion often has no flame rating, and a flame-rated material is often not a bonding tape at all. This grade is engineered for applications that demand both. Its thickness and adhesive type are held as trade secrets, so suitability is confirmed against your application rather than against a published datasheet.

LJIPL Mr.Bond® thermal pads are UL 94V0 approved, described as the highest rating for fire resistance, and can be supplied from 1 W/m·K to 8 W/m·K as per specification. They sit between battery cells and casing, conducting heat while remaining an excellent insulation material. If you have been given a conductivity figure to buy against, what W/m·K means when specifying a thermal pad explains why the gap and the contact pressure matter as much as the number.

No UL 94 classification is published for any other tape in the Mr.Bond® range, and we will not quote one. If your specification needs a class on a material we have not rated, raise it in the enquiry: the honest answer is sometimes that a different product in the range is the one to use.

Is “flame-retardant grade” the same as UL 94 V-0?

No, and the difference is worth holding on to, because the two phrases get used interchangeably in enquiries.

Flame retardant describes a formulation. It means the material has been compounded to resist ignition and to avoid feeding a flame. It is a statement about what the material is made of and how it behaves in general terms.

UL 94 V-0 is a classification against a named test. It means specimens of that material were tested by the method described above and met the limits for that class.

A material can be genuinely flame retardant without carrying a UL 94 classification, usually because it has not been submitted for that test or because the relevant specification called for a different standard. Mr.Bond® Polyimide Tape is a case in point: it is supplied in flame-retardant (FR) grade with outstanding dielectric strength and a Class 180°C thermal rating, and that FR grade is what we publish. We do not publish a UL 94 classification for it. If your drawing calls for a UL 94 class on the nickel-strip insulation specifically, say so when you enquire so the requirement is answered rather than assumed.

Class 180°C, for completeness, is a third and unrelated thing again: a thermal classification describing continuous service capability for electrical insulation, not a flammability rating. Three different labels, three different questions. The insulation carriers and what each one is actually rated for are compared in polyimide, PVC or polyester.

What should you ask for?

Quote the standard and the class as your specification writes them, and say where the material sits. “A UL 94 V-0 bonding tape for a board bonded inside a sealed enclosure” is answerable; “a fireproof tape” is not, because no tape is fireproof in the sense that phrase suggests.

Send with it: the substrates to be bonded or the gap to be filled, the bond area or pad footprint, the continuous operating temperature at that location, and the exact wording of the flammability requirement in your specification, including the edition of the standard if it is named. If a third-party certificate or a declaration is required for your own compliance file, ask for that explicitly at enquiry stage rather than after the order.

Both rated products are manufactured by Lalit Jain Industries Pvt. Ltd. (LJIPL), founded in 1987 and ISO 9001:2015 certified, at two of its own units at Rai, Sonipat (Haryana) and Bawana, Delhi. Custom slitting runs from 12 mm to 1200 mm and samples are available on request. Send the requirement to our engineering team and it will be confirmed against your specification.

Frequently asked questions

What does UL 94 V-0 mean?

UL 94 is the standard classification for the flammability of plastic materials, and V-0 is the most demanding of its vertical burn ratings. A V-0 material stops burning quickly after each ten-second flame application, does not burn up to the holding clamp, and does not drip flaming particles that ignite the cotton indicator beneath the specimen.

Does UL 94 V-0 mean a tape is fireproof?

No. All three V classifications allow a specimen to be ignited and to burn for a period. V-0 says the material self-extinguishes promptly and does not drip flaming particles that start a second fire. It does not say the material is non-combustible, nor that it is safe at any temperature.

What is the difference between V-0, V-1 and V-2?

Two things: how long burning may continue, and whether flaming drips are allowed. V-0 has the shortest afterflame allowance. V-1 allows substantially longer. V-2 allows the same timings as V-1 but also permits flaming particles that ignite the cotton indicator, which is the real distinction between V-1 and V-2.

Why do battery assemblers ask for UL 94 V0 on a tape?

Because a battery pack is a sealed enclosure around a stored-energy device, and a material in direct contact with cells cannot be inspected or replaced once the pack is closed. A flammability class in the specification generally applies to every material inside, so an unrated tape becomes an exception somebody has to justify.

Which Mr.Bond® products are UL 94 V0 approved?

Two: Mr.Bond® 4500 FLR, a fire-proof double-sided tissue tape with excellent adhesion, and LJIPL Mr.Bond® thermal pads, which also offer thermal conductivity from 1 to 8 W/m·K per specification. No UL 94 classification is published for any other tape in the range, and none is claimed.

Is flame-retardant grade the same as UL 94 V-0?

No. Flame retardant describes a formulation compounded to resist ignition and avoid feeding a flame. UL 94 V-0 is a classification against a named test. Mr.Bond® Polyimide Tape is supplied in flame-retardant (FR) grade; a UL 94 classification is not published for it. If your drawing requires one, raise it in the enquiry.

Is Class 180°C a flammability rating?

No. Class 180°C, also written Class H, is a thermal classification for electrical insulation materials and describes continuous service capability rather than behaviour in a flame. It appears on Mr.Bond® Polyimide Tape and on the PTFE-coated fibreglass heat sealing tape. Flammability, thermal class and flame-retardant grade are three separate questions.

What should I send when a flame rating is specified?

The standard and class exactly as your specification writes them, the substrates or the gap, the bond area or pad footprint, the continuous operating temperature at the location, and whether you need a certificate or declaration for your own compliance file. Ask for documentation at enquiry stage rather than after the order.

Still deciding?

Tell us the job, we will tell you the tape

Share the surfaces, the operating conditions and a rough quantity. Our team will recommend a grade and send samples on request.

Chat on WhatsApp